Chattanooga intelect legend xt user manual
To once. The waveform Intensity may be increased or decreased at any time during the session without utilizing this process. Refer to pages 48 once. The following information provides instructions for changing ultrasound treatment parameters during a treatment session. The ultrasound intensity may be increased or decreased at any time during the session without utilizing this process.
Therapy System. The following information provides instructions for changing Combination Treatment Electrotherapy Channel and Ultrasound parameters during a treatment session. The Add Pain Map the body area of the associated pain as desired description is displayed in the Pain window will display.
The following information gives general instructions as to setting up, saving and accessing User Protocols. Should the Default Protocols be restored, through the User Utilities, all User Protocols will be permanently removed from the system. Should the Default Protocols be restored through the User Utilities, all User Protocols will be permanently removed from the system.
Electrotherapy and page 31 for Ultrasound To session. Specifically designed for use with the Intelect Legend XT Therapy Systems, these modules configure the Therapy System to meet many of the therapeutic needs that a clinician may have.
Extended Front Access Panel 2. Module to System Mounting Holes 3. Module to System Feet Alignment Indents 4. Power Cord Routing Port 5. If use is attempted before repairs are made, the System may operate unpredictably and has the potential of causing injury to the patient or damage to There are two different Operator Remotes.
Operator Remote is to be used under Press the M Button on the remote to apply supervision of a physician or licensed Manual Stimulation. Place the storage hook into one of the Remote Storage Indents as shown. Open Storage Bins and place items for storage. The information in this section instructs the owner, operator or user as to the initial setup and operation of the optional NiMH Battery Module.
These are numbered so the user can possibly correct the problem without the aid of service personnel. Page 93 2. Attempted to use an Invalid Patient Data Card. This equipment is to be used only under the prescription and supervision of a licensed practitioner.
Any use of editorial, pictorial, or layout composition of this publication without express written consent from Chattanooga Group of Encore Medical, L. This publication was written, illustrated, and prepared for distribution by Chattanooga Group of Encore Medical, L.
The precautionary instructions found in this section and throughout this manual are indicated by specific symbols. Understand these symbols and their definitions before operating this equipment. The definition of these symbols are as follows:. These Notes are helpful information to aid in the particular area or function being described. Know the limitations and hazards associated with using any electrical stimulation or ultrasound device.
Observe the precautionary and operational decals placed on the unit. Also, determine that the treatment time control does actually terminate ultrasonic power output when the timer reaches zero. Inappropriate handling of the Ultrasound Applicator may adversely affect its characteristics.
Ingress of water or liquids could cause malfunction of internal components of the system and therefore create a risk of injury to the patient. However, there is no guarantee that interference will not occur in a particular installation. Harmful interference to other devices can be determined by turning this equipment on and off.
Try to correct the interference using one or more of the following: reorient or relocate the receiving device, increase the separation between the equipment, connect the equipment to an outlet on a. Federal Law restricts these devices to sale by, or on the order of, a physician or licensed practitioner. This device should be used only under the continued supervision of a physician or licensed practitioner.
Potential electromagnetic or other interference could occur to this or to the other equipment. Try to minimize this interference by not using other equipment in conjunction with it. This includes headache. Errors and Warnings in these categories indicate an internal problem with the system that must be tested by Chattanooga Group or a Field Service Technician certified by Chattanooga Group before any further operation or use of the system. Use of a system that indicates an Error or Warning in.
Consult other resources for additional information regarding the application of Electrotherapy and Ultrasound. Electrodes in contact with each other could result in improper stimulation or skin burns. Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing.
Improper application may result in patient injury. If any question arises as to the proper electrode size, consult a licensed practitioner prior to therapy session.
Electrical current of this magnitude must not flow through the thorax because it may cause a cardiac arrhythmia. Energy from diathermy shortwave, microwave, ultrasound, and laser can be transferred through the implanted neurostimulation system, can cause tissue damage, and can result in severe injury or death. In the event of battery cell rupture or leakage, handle Battery Module wearing neoprene or natural rubber gloves. Contents of a ruptured or leaking battery can cause respiratory irritation.
Hypersensitivity to nickel can cause allergic pulmonary asthma. Should an individual cell from a battery become disassembled, spontaneous combustion of the negative electrode is possible.
There can be a delay between exposure to air and spontaneous combustion. Never attempt to charge the Battery Module on any other charging mechanism. Doing so can increase the individual cell temperature and cause cell rupture or leakage. Never short circuit the battery.
The battery may explode, ignite, leak or get hot causing serious personal injury. The irritation can usually be reduced by using an alternative conductive medium or an alternative electrode placement. Application of therapeutic deep heat for the treatment of selected sub-chronic and chronic medical conditions such as:.
Additional precautions should be used when ultrasound is used on patients with the following conditions:. Ultrasound Applicator- 5 cm 2 Standard. Front Access Panel See Page Below are the definitions for all of the symbols used in the Intelect Legend XT hardware and software.
Study and learn these symbols before any operation of the system. Below are the definitions for all of the unique terminology used throughout this manual. Study these and become familiar with these terms for ease of system operation and familiarization with the components and control functionality of the Intelect Legend XT Therapy System.
Some of these terms and definitions refer to a specific button or control on the system. Refer to page 13 for Symbol Definitions. The dedicated button on the Main unit, below the display, that each time pressed takes the user back one screen at a time. Controls used in various modality parameter screens to navigate or change a value up or down within the parameter. Any optional modular modality component designed for installation onto the System.
That component of the Applicator that makes contact with the patient during Ultrasound or Combination therapy. The component of the Applicator which, when illuminated, indicates if the Sound Head is emitting Ultrasound. TENS waveform output intensities are measured, specified and listed to peak, not peak to peak.
Combination System. Depth Combination and Electrotherapy System. Interferential Current is a medium frequency waveform. Current is distributed through two channels four electrodes. The currents cross each other in the body at the area requiring treatment.
The two currents interfere with each other at this crossing point, resulting in a modulation of the intensity the current intensity increases and decreases at a regular frequency. Output Mode. Electrodes Carrier Frequency. Russian Current is a sinusoidal waveform, delivered in bursts or series of pulses. This method was claimed by its author Kots to produce maximal muscle strengthening effects without significant discomfort to the patient. Electrodes Output Intensity. Off or On Cycle Time.
The Symmetrical Biphasic waveform has a short pulse duration and is capable of strong stimulation of nerve fibers in the skin and in muscle. This waveform is often used in portable muscle stimulation units, and some TENS devices. Because of its short pulse duration, the patient typically tolerates the current well, even at relatively high intensities. Microcurrent is a monophasic waveform of very low intensity that closely simulates the electrical current generated by the human body.
Microcurrent can be applied via electrodes or probe. Electrodes or Probe Output Intensity. Positive, Negative, or Alternating Treatment Time. Electrical current of this. Premodulated Current is a medium frequency waveform. Current comes out of one channel two electrodes. The current intensity is modulated: it increases and decreases at a regular frequency the Amplitude Modulation Frequency.
The waveform is monophasic current flows in one direction only. The high voltage causes a decreased skin. Positive or Negative Ramp. Peak Current or Volts Sweep. Output accuracy. Beam Nonuniformity Ratio. Effective Radiating Areas. Treatment Time. Read and download chattanooga older intelect legend 2c 4c combo user manual free ebooks in pdf format - acadia repair manual toyota 1fz fe engine repair manual. Chattanooga intelect xt and legend combo units and ultrasound, and manuals for physical therapy and therapy patients; isokinetics inc.
No one can service your chattanooga equipment and have it back to you faster than we can!